Showing results: 61 - 75 of 109 items found.
-
CK520A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK562A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK564A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK058F -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK058M -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Novus, Novus-M, & Novus-R 100/25GE Load Modules -
Keysight Network Applications and Security
Novus, Novus-M, and Novus-R are Ixia’s next-generation architecture and test solutions that satisfy the test needs of both high-density, multi-rate switch/router makers and the organizations implementing the network equipment. Supporting eight native QSFP28 100GE ports and up to 32-ports for 25GE per load module, Novus load modules enable interoperability and functional testing, as well as high-port count performance testing.
-
JMeter™ -
The Apache Software Foundation
Apache JMeter may be used to test performance both on static and dynamic resources (Webservices (SOAP/REST), Web dynamic languages - PHP, Java, ASP.NET, Files, etc. -, Java Objects, Data Bases and Queries, FTP Servers and more). It can be used to simulate a heavy load on a server, group of servers, network or object to test its strength or to analyze overall performance under different load types. You can use it to make a graphical analysis of performance or to test your server/script/object behavior under heavy concurrent load.
-
Electronic Specialties Inc.
LoadPro is an external Web load testing service. A LoadPro test simulates actual user traffic from outside your network, stressing your entire infrastructure in order to discover bottlenecks that impact performance under peak traffic.
-
aTCA-3430 -
ADLINK Technology Inc.
The aTCA-3430 is a high performance 10G Fabric switch blade for AdvancedTCAR platforms. This product is ideal for bandwidth intensive telecom applications such as wireless access controllers, DPI/security network, IPTV, IP multimedia subsystems, RNC/BSC, broadband access/bearer networks, data centers, and LTE/4G network applications. The aTCA-3430 provides 10GbE hub-to-node connectivity and integrated switch silicon that supports load balancing, priority queues, packet classification, and flow control to enable strict bandwidth management for implemented applications.
-
aTCA-3710 -
ADLINK Technology Inc.
The aTCA-3710 is a high performance, high bandwidth, 40G Fabric switch blade for AdvancedTCA® platforms. This product is ideal for bandwidth intensive telecom applications such as wireless access controller, DPI/security network, IPTV, IP multimedia subsystem, RNC/BSC, broadband access/bearer network, data center, and LTE/4G network applications. The aTCA-3710 provides 40GbE hub-to-node connectivity and integrated switch silicon that supports load balancing, priority queues, packet classification, and flow control to enable strict bandwidth management for implemented applications.
-
ROM-Elektronik GmbH
High- frequency loads come from the transmission systems of telephone companies (GSM, UMTS, LTE), cordless telephones (DECT telephones), wireless computer networks (WLAN, Bluetooth,...), and radar, radio, TV (DVB), etc. The blood is acidified by this influence and Cell membrane tensions change.
-
Algodue elettronica
UEM1P5-4D R for RS485 Modbus RTU/ASCII communicationUEM1P5-D M for M-Bus communicationUEM1P5-4D E for Ethernet (Modbus TCP) communicationFor 1 or 5A CTProgrammable CT ratioFully bi-directional four quadrants measurements for all energies and powersFor 3 / 4 wire networks with balanced or unbalanced load (UEM1P5-4D R and UEM1P5-4D E only for 4 wire networks)Class B according to EN 50470-3S0 output for energy pulse emissionAvailable with MID certification
-
KHZ43201 -
Beijing KeHuan Century EMC Technology Co,.LTD
The KHZ43201 voltage probe is a standard low resistance test probe, which meets the technical requirements for this product in the CISPR16-1 and CISPR14-1 test equipment. When measuring the interference voltage of the power grid, the artificial power supply network cannot be used at the load port, and sometimes it is necessary to use a voltage probe to measure the interference of the signal port, the load port, and the antenna port. The input impedance of the voltage probe to the ground wire is greater than 1.5KΩ, which can protect the input terminal of the receiver.
-
TE3000-series -
LBA Group, Inc
The TE3000-series of RF vector network analyzers have full vector measurement capability, and accurately resolves the resistive, capacitive and inductive components of a load. The user can display the vector impedance plus a range of related parameters including SWR, reflection coefficient, return loss and R-L-C equivalent circuit.
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Network analyzers are used to measure so-called scatter parameters (S-parameters). These describe the behaviour of electrical components with the help of wave magnitudes. Whether simple cables, filters, amplifiers or complex subsystems, the following applies to all these components: Different loads can have unseen effects on the measured values over time.